There are four possible mounting configurations depending upon space constraints.
Attention ! Over the size of the radius R ( see detail X ) can be adjusted the resistance to mount and remount the fan with sleeves.
Dim mm |
A |
B |
C1 |
C2 |
D |
R |
W |
X |
for LM-40...
|
32
|
5.0
|
6.5
|
4.5
|
5.75
|
0.5~1.0
|
14.5° |
Form / dim. dependent on fan manufacturer |
for LM-60...
|
50
|
5.5
|
7.5
|
5.0
|
6.5
|
0.5~1.0
|
10,5° |
Form / dim. dependent on fan manufacturer |
for LM-80...
|
71.5
|
6.5
|
8.0
|
6.0
|
7.25
|
0.5~1.0
|
8° |
Form / dim. dependent on fan manufacturer |
for LM-92...
|
82.5
|
6.5
|
8.5
|
6.0
|
7.5
|
0.5~1.0
|
7°
|
Form / dim. dependent on fan manufacturer |
for LM-119...
|
105
|
8.5
|
11.0
|
8.0
|
9.5
|
1.0~2.0
|
7°
|
Form / dim. dependent on fan manufacturer |

Hole cut-out 1
First pull the sleeve over the flange of the fan, then place the four mushroom shaped pegs over the holes B and then push through the mounting plate
(a little lubricant would assist).

Hole cut-out 2
First place the four mushroom shaped pegs through the 45° slots of the mounting plate and push into the holes C2. Now put the fan into the sleeve and pull the corners over the fan flanges.